Quantcast
Channel: ProjectWise Design Integration Wiki
Viewing all articles
Browse latest Browse all 994

Last Error 112233 CONNECTION Client could not be accessed- unknown error occurred.Failed to retrieve a login token from CONNECTION Client.

$
0
0
Revision 5 posted to Content Management Wiki by Franky Riphung on 7/28/2020 9:02:26 PM
Product(s):ProjectWise Design Integration
 Version(s):10.00.03.49
 Environment:N\A
 Area:N/A
 Subarea:N\A

Error or Warning Message

Last Error 112233 CONNECTION Client could not be accessed- unknown error occurred.

Failed to retrieve a login token from CONNECTION Client.

Explanation

Might happen when logging into ProjectWise Explorer with Bentley IMS credentials.

How to Avoid

  1. Have user verify if they are registered to the organization by going here: https://ims.bentley.com/IMS/Profile
  2. If the organization field is empty in the profile, an admin will need to add them to the organization via user management tool
  3. Have user log out and log back into CONNECTION Client
  4. If the issue still occurs do the following:
    1. Open the task manager and select the Bentley Licensing Service and end task
    2. Select the Bentley.Connect.Client and end task
    3. Delete the MySELECT.db file found in %localappdata%\Bentley\
    4. Relaunch the CONNECTION Client

---------------------------------------------------------------------------------------------------------------------

Additional troubleshooting steps:

- Uninstall CONNECTION Client
- Navigate to C:\Program Files (x86)\Common Files\Bentley Shared - rename the CONNECTION Client folder
- Reboot the Machine
- Reinstall CONNECTION Client