Current Revision posted to Project Delivery: Content Management Wiki by Thomas Hess on 8/2/2016 2:44:29 PM
Product(s): | ProjectWise Client V8i | ||
Version(s): | 08.11.07.133 | ||
Area: | Explorer | ||
Original Author: | Bentley Technical Support Group |
Problem
Datasources not displaying in ProjectWise Explorer. You will see the plus sign then it disappears.
Solution
Once we Hard checked the Prevent UDP for DNS and Listing Network Configuration Settings | General Tab we were able to see the datasources.
Other messages we saw in the PWC.log file included:
• Error 32768 "failed to refresh DNS/datasource name cache
• 2010-08-23 12:55:35,395 ERROR pwise.netapi.routecache - cannot map gateway/endpoint
• 2010-08-23 12:55:35,395 ERROR pwise.netapi.discovery - failed to parse DNS response from host
See Also
External Links
Bentley Technical Support KnowledgeBase
Comments or Corrections?
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
Tags: explorer, ProjectWise Client V8i, SELECTsupport