Quantcast
Channel: ProjectWise Design Integration Wiki
Viewing all articles
Browse latest Browse all 994

Move Temp async extraction folder

$
0
0
Revision 2 posted to Project Delivery: Content Management Wiki by Thomas Hess on 8/3/2016 3:51:46 PM

 Product(s):ProjectWise Integration Server
 Version(s):08.11.11.111
 Area: Integration / Caching /Gateway
 Subarea: MISC
 Original Author:Dana Guthrie, Bentley Technical Support Group

Problem

Move Temp async extraction folder for full text indexing

Product: ProjectWise Server V8i
Version: 08.11.11.111
Area: Index Server, Problem ID#: 88714, GENERALINFORMATION



Solution

Perform the following in this order:

1. Stop the Microsoft indexing service and PW Orchestration service
2. In the registry editor go the following key and change the path
3. HKEY_LOCAL_MACHINE\SOFTWARE\Bentley\ProjectWise\Automated File
4. Processing\ExtractionTempDir
5. Restart the services

Tags: indexing, Migrated, ProjectWise, SELECTsupport