Current Revision posted to ProjectWise Design Integration Wiki by Dana Guthrie on 9/30/2022 5:59:05 PM
Product(s): | ProjectWise V8i | ||
Version(s): | 08.11.05.16 | ||
Area: | Network | ||
Original Author: | Bentley Technical Support Group |
Problem Description
"The Gateway server failed to connect to the remote endpoint". The remote client cannot check out documents from the remote storage area.
Solution
The problem is that Port 5800 at the remote storage site is only open to the San Jose Site. Port 5800 is closed to other sites. The solution was to re-route the remote client request through the Integration server in San Jose.
See Also
External Links
Bentley Technical Support KnowledgeBase
Comments or Corrections?
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
Tags: SELECTservices, ProjectWise