Current Revision posted to ProjectWise Design Integration Wiki by Dana Guthrie on 12/6/2022 1:06:59 PM

Problem

A user is unable to open a MicroStation file from ProjectWise, getting an Error 222. 

Solution

1. Verify the Program association: First check which Application your file is defined as on the Document>Properties.  Then go to Tools>Associations>Programs and make sure that the association for that given application is using the correct MicroStation. If a user has manually added a Program association then remove it and try to verify the error persist.

2. If a user is newly created then verify that he is having Read/Write access to an all Workspace folder.  (Seek help from ProjectWise Administrator if required)

3. Try using different PW login on the same system.

4. If PW is recently updated then check if a user is having a compatible version of Microstation. 

Check ProjectWise Version Support Matrix

5. Try opening a Microstation file outside a ProjectWise, then import back to PW then try opening a file. 

If you have tried all the above solutions and still get the error then submit your Service request here. 

-TSE