Quantcast
Channel: ProjectWise Design Integration Wiki
Viewing all 994 articles
Browse latest View live

Installation - ProjectWise Explorer Client V8i

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Raul Guerrero on 9/30/2016 4:50:43 PM

ConnectClientWrapperNative.VC100.dll is missing from your computer.

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Raul Guerrero on 9/30/2016 4:50:44 PM
Product(s):ProjectWise Explorer Client V8i
Version(s):08.11.11.84
Environment:Windows 7 64 bit
Area:Installation
Subarea:N\A

Problem Description

The program can’t start because ConnectClientWrapperNative.VC100.dll is missing from your computer.

Steps to Resolve1.     Backup, then delete the following key:

  1. a.       hklm\software\wos6432Node\Bentley\ProjectWise\10.00 key

  2. Uninstall PW Explorer C.E. software

  3. Delete PW Directory from PF and PFx86

  4. Empty recycling bin

  5. Reboot

  6. Reinstall PW Explorer .590

See Also

XXXXXXX(Add links as needed for other relevant Be Communities content.)XXXXXXX

 Original Author:Raul Guerrero
Tags: 08.11.11.84, InstallationWindows 7 64 bit, ProjectWise, ProjectWise Explorer Client V8i, en, SELECTsupport

Failed to delete the user.

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Molly Watts on 10/3/2016 6:30:12 PM

 Product(s):ProjectWise Integration Server
 Version(s):08.11.11.559
 Area: ProjectWise Administrator
 Subarea: User Management
 Original Author:dana guthrie, Bentley Technical Support Group

Error or Warning Message

Failed to delete the user. Invalid argument passed to dmsapi function
Failed to delete the user. Failed to send client request
Failed to delete the user. Not found.
Failed to delete the user. Unique constraint violated

Explanation

User is attempting to delete users from Projectwise Administrator and gets error

There are instances where it is impossible to delete a user sync account. Attempts of deleting the User account resulted in the above errors

How to Avoid

Remove any of the user properties on the account (Description, E-mail, and group information in Member of) before removing the account. If the error returns, press F5 to refresh the User screen to clear the error and then click remove to remove the account.

If the user still appears, and you are now getting
Failed to delete the user. Not found.
Failed to delete the user. Unique constraint violated

Its possible the list is cached, and you just need to clear the cache. It may be necessary to refresh the screen or you may need to close out of Admin and relaunch. 
Otherwise try stopping and restarting the integration server service

Also check to see if the user currently has any files checked out to them, free those files and try the delete again

See Also

ProjectWise V8i - Failed to delete user

Tags: ProjectWise Administrator, User Management, error message, ProjectWise Integration Server, SELECTsupport

Unable to see datasources on Windows 10

$
0
0
Revision 1 posted to Project Delivery: Content Management Wiki by Dana Guthrie on 10/31/2016 7:00:15 PM

 Product(s):ProjectWise Administrator
 Version(s):08.11.11.590
 Area: ProjectWise Administrator
 Subarea: Application Configurations
 Original Author:Dana Guthrie, Bentley Technical Support Group

Background

I am unable to see the datasources from my windows 10 workstation using ProjectWise Administrator SS4 08.11.11.590

Solution

ProjectWise Administrator and ProjectWise Explorer SS4 version(s) are not supported on Windows 10 operating system.

To be able to see the ProjectWise datasources on a SS4 08.11.11.590 server:

  1. Uninstall all ProjectWise SS4 software from the client machine (Explorer and Admin)
  2. Install the ProjectWise Connect Edition 10.00.01.67 version of both the Explorer and Admin.
  3. When you launch ProjectWise Admin connect edition and login to an older (SS4) datasource, you will be prompted with a message:
  4. "The server you are connecting to is running a different version of ProjectWise.  ProjectWise Administrator only supports connections to the Matching version of ProjectWise Integration Server.  If you proceed, full administrative capabilities may not be available."  This just means that any new capabilities that may be in the connect edition will not work with older datasource.
  5. Click okay to the message. 

Note: You cannot mix versions of ProjectWise on a single machine.  In other words you can not have PWE SS4 installed with PW admin Connect edition.  Explorer and Admin must be of the same version.

See Also

Integration / Caching /Gateway - ProjectWise Design Integration V8i

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Molly Watts on 12/19/2016 2:15:49 PM

Installation - Integration / Caching /Gateway - ProjectWise Design Integration V8i

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Molly Watts on 12/19/2016 2:20:24 PM

ProjectWise Fails to Start in Secure Mode

$
0
0
Revision 1 posted to Project Delivery: Content Management Wiki by Molly Watts on 12/19/2016 2:20:25 PM
 Product(s):ProjectWise Design Integration V8i
 Version(s):10.00.01.67
 Environment:N\A
 Area:Integration / Caching /Gateway
 Subarea:Installation

Problem

XXXXXXXProblemXXXXXXX



Solution

XXXXXXXSolutionXXXXXXX



See Also

XXXXXXX(Add more links as needed for other relevant Be Communities content.)XXXXXXX



 Original Author:Molly Watts
Tags: installation, Integration / Caching /Gateway, 10.00.01.67, ProjectWise, en, SELECTsupport, ProjectWise Design Integration V8i

Utilizing Templates in ProjectWise Deliverables Management

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Molly Watts on 12/19/2016 8:44:10 PM

Quite often PWDM users need to send packages to the same distribution list, or use a different default schedule and don't want to reenter the information each time.  This process will show how to utilize drafts as a template to have the information pre populated.

note: this example is based on using the Portal, however the same process can be following when using the ProjectWise Deliverables Management Connector for ProjectWise Explorer

 

  1. Create New Transmittal

     

  2. Enter subject to clearly define the use of the template and any other information that might be used for most of the future transmittals (Purpose, Comments, Cover Letter)

     

     

  3. Select the Recipients tab and Click “Add Recipients” Select the recipients that will be normally be receiving this type of package, and change the “Acknowledge” and “Response” settings per user as necessary

4. Click “Save Draft” 

5. Any internal participant to the project will now be able to log in, and browse to the Drafts page, and use any of the created templates to initiate a New Transmittal

6. Clicking the “Use as a template” button will start a new transmittal with all the information saved in the draft (General, Recipients, Documents, Scheduling) 

7. Change/add any details as needed and issue transmittal

 

Tags: ProjectWise Deliverables Management

PWDM Variables available for the Cover Letter Template

$
0
0
Revision 1 posted to Project Delivery: Content Management Wiki by Molly Watts on 12/21/2016 3:44:42 PM

 

Transmittal variables

Variable

Description

{$Project.Name$}

The name of the CONNECTED project the transmittal is sent from

{$Transmittal.Code$}

Transmittal package ID

{$Transmittal.Subject$}

The subject of the transmittal

{$Transmittal.Comments$}

Transmittal comments

{$Transmittal.Purpose$}

The name of the purpose assigned to this transmittal

{$Transmittal.AcknowledgementDueDate$}

The date that acknowledgement for this transmittal is due

{$Transmittal.ResponseDueDate$}

The date that responses for this transmittal are due

{$Transmittal.CreatedDate$}

The date the transmittal was created

{$Transmittal.CurrentDate$}

The date the cover letter was generated (generally the transmittal issue date)

{$Transmittal.CurrentUserFullname$}

The name of the user who issued the transmittal

{$Transmittal.CurrentUserOrganization$}

The name of the company that the transmittal issuer belongs to

{$Transmittal.CurrentUserEmail$}

The email address of the transmittal issuer

 

Document variables

Variable

Description

{$Document.FileName$}

File name

{$Document.FileSize$}

File size

{$Document.Name$}

Document name

{$Document.Path$}

Document path in the transmittal package

{$Document.ReferenceOf$}

Name of document this document is a reference of

 

Document attribute values

Depends on the attributes configured in the portal settings. Below are only examples.

Variable

Description

{$DocumentAttribute.GetValue(Description)$}

Document description

{$DocumentAttribute.GetValue(State)$}

Document state

{$DocumentAttribute.GetValue(Version)$}

Document version

 

Reference document variables

Variable

Description

{$Reference.FileName$}

Reference file name

{$Reference.FileSize$}

Reference file size

{$Reference.Name$}

Reference document name

{$Reference.Path$}

Reference path in the package

{$Reference.ReferenceOf$}

Name of document this reference is a reference of

 

Reference attribute values

Depends on the attributes configured in the portal settings. Below are only examples.

Variable

Description

{$ReferenceAttribute.GetValue(State)$}

Document state

{$ReferenceAttribute.GetValue(Version)$}

Document version

 

Transmittal recipient variables

Variable

Description

{$Recipient.Comments$}

Comments entered about the recipient

{$Recipient.Company$}

The name of the organization the recipient belongs to

{$Recipient.e-mail$}

The recipient's email address

{$Recipient.Name$}

The recipient's name

{$Recipient.ResponseRequired$}

Indicates if the recipient is required to respond - Substituted with "Y" or "N"

{$Recipient.Title$}

The recipient's title

 

Folder variables

Variable

Description

{$Folder.Name$}

Folder name in the transmittal package

{$Folder.Path$}

Folder path in the transmittal package

 

Repeater variables

Variable

Description

{$Formula$}{$DocumentRepeater.Index$} + 1

Indicates that this template line needs to be repeated for every document in the transmittal.

{$Formula$}{$FolderRepeater.Index$} + 1

Indicates that this template line needs to be repeated for every folder in the transmittal.

{$Formula$}{$RecipientRepeater.Index$} + 1

Indicates that this template line needs to be repeated for every recipient in the transmittal.

{$Formula$}{$ReferenceRepeater.Index$} + 1

Indicates that this template line needs to be repeated for every reference in the transmittal.

Tags: ProjectWise Deliverables Management

Incorrect sizes generated when creating iCS for PDF renditions

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by marion powell on 12/27/2016 3:25:21 PM
Product(s):Bentley i-model Composition Server
Version(s):08.11.11.590
Environment:N\A
Area:N/A
Subarea:N\A

Problem Description

When I submit a PDF Rendition, the size of the pdf is incorrect.  It does not correspond to the paper size set in the settings file being used in the Source File Presentation in PW Admin.

Steps to Resolve

  1. An invalid printer was set in the IP.CFG file on the iCS for PDF server. Setting the IP_DCS_RENDITION_PRINTER variable to the default settings of "ProjectWise Dynamic Composition Server" corrected the problem.
  2. IP.CFG is located in the following directory on the iCS for PDF server: C:\Program Files (x86)\ProjectWise InterPlot Organizer\config
 Original Author:Marion Powell
Tags: 08.11.11.590, Bentley i-model Composition Server, ProjectWise, en, SELECTsupport

Integration - AutoCAD - ProjectWise Explorer Client V8i

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Van Kendall on 12/29/2016 7:41:37 PM

Enable / Disable integration - Integration - AutoCAD - ProjectWise Explorer Client V8i

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Van Kendall on 12/29/2016 7:42:20 PM

Getting error, "Exception in idacad19_1odma.arx ARX Command" opening AutoCad 2014 files.

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Van Kendall on 12/29/2016 7:42:20 PM
 Product(s):ProjectWise Explorer Client V8i
 Version(s):08.11.11.605
 Environment:Windows 7 64 bit
 Area:Integration - AutoCAD
 Subarea:Enable / Disable integration

Problem

User is getting the following error when opening AutoCad files from ProjectWise Explorer V8i SS4 version 08.11.11.605. The user has AutoCad 2014 loaded with the ProjectWise Integration Module for Autodesk AutoCAD 2104 version 08.11.11.749

 
"Exception in idacad19_1odma.arx ARX Command"
"Unhandled Exception C0000005 (Access Violation Reading 0x0000) at address 9718EC58h"
 

Solution

Removing the ProjectWise Integration Module for Autodesk AutoCAD 2104 version 08.11.11.749 and loading the ProjectWise Integration Module for AutoCAD 2014 version 08.11.11.855 fixed the issue.





 Original Author:Van Kendall
Tags: Enable / Disable integrationWindows 7 64 bit, 08.11.11.590, Integration - AutoCAD, ProjectWise, ProjectWise Explorer Client V8i, en, SELECTsupport

MISC - ProjectWise Explorer Client V8i

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Raul Guerrero on 12/30/2016 1:48:13 AM

Last Error 58030 Unable to create new document version

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Raul Guerrero on 12/30/2016 1:48:13 AM
Product(s):ProjectWise Explorer Client V8i
Version(s):10.00.01.67
Environment:Windows 7 64 bit
Area:MISC
Subarea:N\A

Problem Description

Last Error 58030
Unable to create new document version.
Unable to create a directory for document version.
Getting Last error 58030, couldn't create folder when attempting to version a file.
The problem started when IP addresses were changed. The caching server was given a new IP address as well. The user has modified all DMSconfigs to the new IP address.
Steps to Resolve

Steps To Resolve

DNS issue. Had user report findings to their network group.
This issue was resolved when the old IP address was found in the Hosts file in the ProjectWise Integration server. Once they updated the Hosts file everything starting working as expected.

 

See Also

http://communities.bentley.com/products/projectwise/content_management/w/wiki/13671.error-58060-error-creating-a-new-folder-cannot-createdelete-folders-solution-500000090006

 Original Author:Raul Guerrero
Tags: MISCWindows 7 64 bit, 10.00.01.67, ProjectWise, ProjectWise Explorer Client V8i, en, SELECTsupport

Field Data Management

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Jesse Dringoli on 1/3/2017 2:31:19 PM

This is a placeholder article for Field Data Management

Example article on Field Data Management

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Jesse Dringoli on 1/3/2017 2:32:01 PM

Just a test article

Another example article

$
0
0
Revision 1 posted to Project Delivery: Content Management Wiki by Jesse Dringoli on 1/3/2017 2:32:15 PM

Just a test

Bentley i-model Composition Server V8i

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Jesse Dringoli on 1/3/2017 3:32:16 PM

Folder descriptions displaying instead of name?

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Molly Watts on 1/6/2017 3:07:28 PM

Original Question: Folder descriptions displaying instead of name? by Martin Aitken

I (and others) have folder description being displayed in the tree view instead of the names.

I have been told to untick the "Display Descriptions" box in the Setting tab but I do not have that option available.  This is the view I have had since getting access to PW so I haven't changed anything myself.

Can someone advise please?

Thanks

 


Verified Answer: RE: Folder descriptions displaying instead of name? by Jeff Burrill

It appears that your account isn't granted the option to "Allow user to change settings" in the User Interface node (where the setting "Display descriptions" resides), which is why it does not appear in the node list. In fact, with the exception of Document List, it looks like your account is not permitted to make changes to any of the other settings nodes.

If you are an administrator you can make the change in ProjectWise Administrator. If not, you'll need to talk to your ProjectWise admin person to get the setting changed.


Question: RE: Folder descriptions displaying instead of name? by Martin AitkenThanks Jeff, I have contacted the administrator to see if they can do this for me
Question: RE: Folder descriptions displaying instead of name? by JRODLook under your User options, settings tab, User Interface then look for "Display Descriptions" if it is checked you will see Descriptions instead of file or Project names.

Viewing all 994 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>